Rheem R-410a

Rheem RQPM-A043JK005AUA Heat Pumps
Rheem RQPM-A043JK005AUA Heat Pumps

The 2-5 ton Rheem 14 SEER RQPM & 15/16 SEER RQRM. Dedicated Horizontal Package Heat Pump units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International. The Scroll® CompressorAll of our residential package units, regardless of efficiency level, feature the Scroll Compressor. These scroll compressors use a more advanced technology than traditional reciprocating compressors. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. The RQRM- A060 uses a two stage scroll compressor. It is externally mounted on rubber grommets to reduce vibration and noise. They have fewer moving parts, and they are quieter, more efficient, and longer lasting, and quiet operation. Durable Cabinet with Louvered CondenserCompartment. Our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a One-piece top with a drip lip to help keep water off of the unit sides. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. Access panels have “weep holes” and channels to further help manage water run-off. Side and down discharge options available on all models. (Shipped Downflow Standard). Easily accessible blower section complete with slide-out blower. Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models. Grille/Fan Motor MountOur mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. Easily Accessible Control BoxOperational controls are “up front” for quick installation and easy service diagnostics. Matched Blower/Evaporator Coil Unit . The blower is responsible for the flow of air into your duct work. It has been designed to match the MultiFlex® evaporator coil and other system components for maximum efficiency and quiet operation. In addition, the coil features rifled copper tubing and enhanced fins for improved efficiency. Service FittingsExterior service fittings enable a serviceman to quickly determine unit operating conditions. Supplemental Electric Heating StripsSupplemental electric heat strips up to 20 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring simplifies installation. Other BenefitsPackage heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temperature, and compressor run-time to determine when a defrost cycle is required. Rugged base rails included for improved installation and handling. Low pressure control standard on all models. High pressure control standard on all 5 ton models.      

Rheem RJNL-B120DL040 Heat Pumps
Rheem RJNL-B120DL040 Heat Pumps

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Convertible airflow. TXV refrigerant metering system. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Supplemental electric heat provides 100% efficient heating.  

Rheem RJNL-B120CL040 Heat pumps
Rheem RJNL-B120CL040 Heat pumps

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Convertible airflow. TXV refrigerant metering system. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Supplemental electric heat provides 100% efficient heating.  

Rheem RJNL-B120YL000 Heat Pumps
Rheem RJNL-B120YL000 Heat Pumps

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Convertible airflow. TXV refrigerant metering system. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Supplemental electric heat provides 100% efficient heating.    

Rheem RJNL-B120CL015 Heat Pumps
Rheem RJNL-B120CL015 Heat Pumps

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Convertible airflow. TXV refrigerant metering system. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Supplemental electric heat provides 100% efficient heating.  

Rheem RJNL-B120CM030 Heat Pumps
Rheem RJNL-B120CM030 Heat Pumps

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Convertible airflow. TXV refrigerant metering system. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Supplemental electric heat provides 100% efficient heating.  

Rheem RQPM-A043CK020AUA Heat Pumps
Rheem RQPM-A043CK020AUA Heat Pumps

The 2-5 ton Rheem 14 SEER RQPM & 15/16 SEER RQRM. Dedicated Horizontal Package Heat Pump units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International. The Scroll® CompressorAll of our residential package units, regardless of efficiency level, feature the Scroll Compressor. These scroll compressors use a more advanced technology than traditional reciprocating compressors. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. The RQRM- A060 uses a two stage scroll compressor. It is externally mounted on rubber grommets to reduce vibration and noise. They have fewer moving parts, and they are quieter, more efficient, and longer lasting, and quiet operation. Durable Cabinet with Louvered CondenserCompartment. Our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a One-piece top with a drip lip to help keep water off of the unit sides. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. Access panels have “weep holes” and channels to further help manage water run-off. Side and down discharge options available on all models. (Shipped Downflow Standard). Easily accessible blower section complete with slide-out blower. Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models. Grille/Fan Motor MountOur mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. Easily Accessible Control BoxOperational controls are “up front” for quick installation and easy service diagnostics. Matched Blower/Evaporator Coil Unit . The blower is responsible for the flow of air into your duct work. It has been designed to match the MultiFlex® evaporator coil and other system components for maximum efficiency and quiet operation. In addition, the coil features rifled copper tubing and enhanced fins for improved efficiency. Service FittingsExterior service fittings enable a serviceman to quickly determine unit operating conditions. Supplemental Electric Heating StripsSupplemental electric heat strips up to 20 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring simplifies installation. Other BenefitsPackage heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temperature, and compressor run-time to determine when a defrost cycle is required. Rugged base rails included for improved installation and handling. Low pressure control standard on all models. High pressure control standard on all 5 ton models.  

Rheem RLNN-A060DK020ADG Packaged Unit
Rheem RLNN-A060DK020ADG Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A060CM020BYA Packaged Unit
Rheem RLNN-A060CM020BYA Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A036DK010APA Packaged Unit
Rheem RLNN-A036DK010APA Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A060CM024CXG packaged unit
Rheem RLNN-A060CM024CXG packaged unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A036CL000 Packaged Unit
Rheem RLNN-A036CL000 Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A060DL015BJF Packaged Unit
Rheem RLNN-A060DL015BJF Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A036DK010BJF Packaged Unit
Rheem RLNN-A036DK010BJF Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A060DM000APA Packaged Unit
Rheem RLNN-A060DM000APA Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A036DL000APF Packaged Unit
Rheem RLNN-A036DL000APF Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RLNN-A048CM000ADA Packaged Unit
Rheem RLNN-A048CM000ADA Packaged Unit

Features:R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on all models. (Except 5 ton 15 SEER) which utilizes two stage scroll. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, Micro Channel designed evaporator coil facilitates easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service. Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. One piece top cover and one piece base pan with drawn supply and return opening for superior water management. Externally mounted refrigerant gauge ports for easy service diagnostics. Factory or field-installed electric heat kits available up to 24 kW. Easy to install plug-in; slip in, 100% fully modulating economizer. Forkable base rails for easy handling and lifting. Single point electrical and gas connections. Direct drive or high performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 1 inch filter standard with slide out design. Colored and labeled wiring. Copper tube/Aluminum Fin coils. Molded compressor plug. Micro Channel evaporator and condenser delivers superior performance with less refrigerant charge and less weight than conventional copper tube/aluminum fin coils. In addition the all aluminum construction has superior protection against formicary corrosion and aluminum tube rubbing potential. Its easier to clean and has a more robust surface.

Rheem RKNL-C151DL25EJDA Packaged Unit
Rheem RKNL-C151DL25EJDA Packaged Unit

The 6-12.5 ton Rheem 3 phase RKNL-B, RKNL-C Package Gas/Electric units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International.Benefits:ClearControl™Factory Installed ClearControl™, a Direct Digital Control (DDC) and sensors which can connect to LonWorks™ or BACnet® BAS systems for remote monitoring and control.The Scroll® CompressorAll of our residential/commercial package units, regardless of efficiency level, feature the Scroll® Compressor. The scroll compressor uses a more advanced technology than traditional reciprocating compressors.  Scroll compressors with internal line break overload and high pressure protection. Molded compressor plug is standard on all units. Two independent refrigerant circuits each with a scroll compressor provide two stage cooling operation. They have fewer moving parts, and they are quieter, more efficient, and longer lasting. Single stage compressor on C072 model. Dual stage compressor on C090 – C151 models. Durable Cabinet with Louvered Condenser CompartmentOur cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a one-piece top cover and one piece base pan with drawn supply and return opening for superior water management. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Slide Out Indoor fan assembly for added service convenience. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Motor/Fan Motor MountOur motor mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. Furnace CompartmentControl box operational controls are “up front” for quick access and service diagnostics.  The draft inducer motor is specially designed to quietly provide combustion air while simultaneously venting outdoors the combustion products from the furnace heat exchanger. In addition to the draft inducer motor, the in-shot gas burners, gas valve and manifold efficiently regulate the flow of gas for combustion.  These new gas/electric units also feature direct-spark ignition and remote flame sensors for added dependability and efficiencyMatched Blower/Evaporator Coil UnitThe blower is responsible for the flow of air into your ductwork. Aluminum MicroChannel Outdoor Coils and other system components provide maximum efficiency and quiet operation. Single slab, single pass designed evaporator coil facilitate easy cleaning for maintained high efficiencies. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. Tubular Heat Exchanger Our new package gas electric units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. Other BenefitsThere are single point electrical and gas connections on all models. Solid Core liquid line filter drier on each circuit. Rugged base rails are included for improved installation and handling. Complete factory charged, wired and run tested. Cooling operation up to 125 degree F ambient. Convertible airflow TXV refrigerant metering system on each circuit (except on C072). High Pressure and Low Pressure/Loss of charge protection standard on all models. 2 inch filter standard with slide out design. Two stage gas valve, direct spark ignition, and induced draft for efficiency and reliability. Solid state furnace control with on board diagnostics. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Capillary tube refrigerant metering system on each circuit.

Rheem RKNL-B090DN15E Packaged Unit
Rheem RKNL-B090DN15E Packaged Unit

The 6-12.5 ton Rheem 3 phase RKNL-B, RKNL-C Package Gas/Electric units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International.Benefits:ClearControl™Factory Installed ClearControl™, a Direct Digital Control (DDC) and sensors which can connect to LonWorks™ or BACnet® BAS systems for remote monitoring and control.The Scroll® CompressorAll of our residential/commercial package units, regardless of efficiency level, feature the Scroll® Compressor. The scroll compressor uses a more advanced technology than traditional reciprocating compressors.  Scroll compressors with internal line break overload and high pressure protection. Molded compressor plug is standard on all units. Two independent refrigerant circuits each with a scroll compressor provide two stage cooling operation. They have fewer moving parts, and they are quieter, more efficient, and longer lasting. Single stage compressor on C072 model. Dual stage compressor on C090 – C151 models. Durable Cabinet with Louvered Condenser CompartmentOur cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a one-piece top cover and one piece base pan with drawn supply and return opening for superior water management. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Slide Out Indoor fan assembly for added service convenience. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Motor/Fan Motor MountOur motor mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. Furnace CompartmentControl box operational controls are “up front” for quick access and service diagnostics.  The draft inducer motor is specially designed to quietly provide combustion air while simultaneously venting outdoors the combustion products from the furnace heat exchanger. In addition to the draft inducer motor, the in-shot gas burners, gas valve and manifold efficiently regulate the flow of gas for combustion.  These new gas/electric units also feature direct-spark ignition and remote flame sensors for added dependability and efficiencyMatched Blower/Evaporator Coil UnitThe blower is responsible for the flow of air into your ductwork. Aluminum MicroChannel Outdoor Coils and other system components provide maximum efficiency and quiet operation. Single slab, single pass designed evaporator coil facilitate easy cleaning for maintained high efficiencies. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. Tubular Heat Exchanger Our new package gas electric units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. Other BenefitsThere are single point electrical and gas connections on all models. Solid Core liquid line filter drier on each circuit. Rugged base rails are included for improved installation and handling. Complete factory charged, wired and run tested. Cooling operation up to 125 degree F ambient. Convertible airflow TXV refrigerant metering system on each circuit (except on C072). High Pressure and Low Pressure/Loss of charge protection standard on all models. 2 inch filter standard with slide out design. Two stage gas valve, direct spark ignition, and induced draft for efficiency and reliability. Solid state furnace control with on board diagnostics. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Capillary tube refrigerant metering system on each circuit.

Rheem RKNL-C151CM15E Packaged Unit
Rheem RKNL-C151CM15E Packaged Unit

The 6-12.5 ton Rheem 3 phase RKNL-B, RKNL-C Package Gas/Electric units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. The design is certified by CSA International.Benefits:ClearControl™Factory Installed ClearControl™, a Direct Digital Control (DDC) and sensors which can connect to LonWorks™ or BACnet® BAS systems for remote monitoring and control.The Scroll® CompressorAll of our residential/commercial package units, regardless of efficiency level, feature the Scroll® Compressor. The scroll compressor uses a more advanced technology than traditional reciprocating compressors.  Scroll compressors with internal line break overload and high pressure protection. Molded compressor plug is standard on all units. Two independent refrigerant circuits each with a scroll compressor provide two stage cooling operation. They have fewer moving parts, and they are quieter, more efficient, and longer lasting. Single stage compressor on C072 model. Dual stage compressor on C090 – C151 models. Durable Cabinet with Louvered Condenser CompartmentOur cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a one-piece top cover and one piece base pan with drawn supply and return opening for superior water management. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Slide Out Indoor fan assembly for added service convenience. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Motor/Fan Motor MountOur motor mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. Furnace CompartmentControl box operational controls are “up front” for quick access and service diagnostics.  The draft inducer motor is specially designed to quietly provide combustion air while simultaneously venting outdoors the combustion products from the furnace heat exchanger. In addition to the draft inducer motor, the in-shot gas burners, gas valve and manifold efficiently regulate the flow of gas for combustion.  These new gas/electric units also feature direct-spark ignition and remote flame sensors for added dependability and efficiencyMatched Blower/Evaporator Coil UnitThe blower is responsible for the flow of air into your ductwork. Aluminum MicroChannel Outdoor Coils and other system components provide maximum efficiency and quiet operation. Single slab, single pass designed evaporator coil facilitate easy cleaning for maintained high efficiencies. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. Tubular Heat Exchanger Our new package gas electric units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. Other BenefitsThere are single point electrical and gas connections on all models. Solid Core liquid line filter drier on each circuit. Rugged base rails are included for improved installation and handling. Complete factory charged, wired and run tested. Cooling operation up to 125 degree F ambient. Convertible airflow TXV refrigerant metering system on each circuit (except on C072). High Pressure and Low Pressure/Loss of charge protection standard on all models. 2 inch filter standard with slide out design. Two stage gas valve, direct spark ignition, and induced draft for efficiency and reliability. Solid state furnace control with on board diagnostics. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Capillary tube refrigerant metering system on each circuit.

vfd