Rheem RQRM-A060JK015 Packaged Unit

Technical Specification

Features:
  • Make: Rheem
  • Model code: RQRM-A060JK015
  • Series: RQRM - Series
  • Electrical: 208-230/1/60 V/phase/Hz
  • Refrigerant Type: R-410a
Additional info:

The 2-5 ton Rheem 14 SEER RQPM & 15/16 SEER RQRM Dedicated Horizontal Package Heat Pump units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified.  Additional Benefits The Scroll® Compressor. All of our residential package units, regardless of efficiency level, feature the Scroll Compressor. These scroll compressors use a more advanced technology than traditional reciprocating compressors. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. The RQRM- A060 uses a two stage scroll compressor. It is externally mounted on rubber grommets to reduce vibration and noise. They have fewer moving parts, and they are quieter, more efficient, and longer lasting, and quiet operation. Durable Cabinet with Louvered Condenser Compartment. Our cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a One-piece top with a drip lip to help keep water off of the unit sides. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. Access panels have “weep holes” and channels to further help manage water run-off. Easily accessible blower section complete with slide-out blower. Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models. Grille/Fan Motor Mount. Our mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. Easily Accessible Control Box. Operational controls are “up front” for quick installation and easy service diagnostics. Matched Blower/Evaporator Coil Unit. The blower is responsible for the flow of air into your duct work. It has been designed to match the MultiFlex® evaporator coil and other system components for maximum efficiency and quiet operation. In addition, the coil features rifled copper tubing and enhanced fins for improved efficiency. Service Fittings. Exterior service fittings enable a serviceman to quickly determine unit operating conditions. Supplemental Electric Heating Strips. Supplemental electric heat strips up to 20 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring simplifies installation. Other Benefits Package heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temperature, and compressor run-time to determine when a defrost cycle is required. Rugged base rails included for improved installation and handling. Low pressure control standard on all models. High pressure control standard on all 5ton models.

Read more
Make Rheem
Manufacturer Rheem Manufacturing
Category Cooling>Packaged Units/RTU
Model code RQRM-A060JK015
Series RQRM - Series
Electrical 208-230/1/60 V/phase/Hz
Refrigerant Type R-410a
Weight 481 lbs
Dimensions Height: 41.5 inches
Width: 34 inches
Depth: 59.88 inches
Additional info

The 2-5 ton Rheem 14 SEER RQPM & 15/16 SEER RQRM Dedicated Horizontal Package Heat Pump units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified.  Additional Benefits The Scroll® Compressor. All of our residential package units, regardless of efficiency level, feature the Scroll Compressor. These scroll compressors use a more advanced technology than traditional reciprocating compressors. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. The RQRM- A060 uses a two stage scroll compressor. It is externally mounted on rubber grommets to reduce vibration and noise. They have fewer moving parts, and they are quieter, more efficient, and longer lasting, and quiet operation. Durable Cabinet with Louvered Condenser Compartment. Our cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a One-piece top with a drip lip to help keep water off of the unit sides. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. Access panels have “weep holes” and channels to further help manage water run-off. Easily accessible blower section complete with slide-out blower. Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models. Grille/Fan Motor Mount. Our mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise. Easily Accessible Control Box. Operational controls are “up front” for quick installation and easy service diagnostics. Matched Blower/Evaporator Coil Unit. The blower is responsible for the flow of air into your duct work. It has been designed to match the MultiFlex® evaporator coil and other system components for maximum efficiency and quiet operation. In addition, the coil features rifled copper tubing and enhanced fins for improved efficiency. Service Fittings. Exterior service fittings enable a serviceman to quickly determine unit operating conditions. Supplemental Electric Heating Strips. Supplemental electric heat strips up to 20 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring simplifies installation. Other Benefits Package heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temperature, and compressor run-time to determine when a defrost cycle is required. Rugged base rails included for improved installation and handling. Low pressure control standard on all models. High pressure control standard on all 5ton models.

Download PDF version Download PDF version