Rheem RLNL-G180CR000ARH Packaged Unit

Technical Specification

Features:
  • Make: Rheem
  • Model code: RLNL-G180CR000ARH
  • Series: RLNL - G Series
  • Electrical: 208-230/3/60 V/phase/Hz
  • Refrigerant Type: R-410a
Additional info:

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Dual stage compressor on all models. Convertible airflow – vertical downflow or horizontal sideflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintaining high efficiencies. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting.  

Read more
Make Rheem
Manufacturer Rheem Manufacturing
Category Cooling>Packaged Units/RTU
Model code RLNL-G180CR000ARH
Series RLNL - G Series
Electrical 208-230/3/60 V/phase/Hz
Refrigerant Type R-410a
Additional info
  • R-410A HFC refrigerant.
  • Complete factory charged, wired and run tested.
  • Scroll compressors with internal line break overload and high-pressure protection.
  • Dual stage compressor on all models.
  • Convertible airflow – vertical downflow or horizontal sideflow.
  • TXV refrigerant metering system on each circuit.
  • High Pressure and Low Pressure/Loss of charge protection standard on all models.
  • Solid Core liquid line filter drier on each circuit.
  • Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintaining high efficiencies.
  • Cooling operation up to 125 degree F ambient.
  • Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream.
  • Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers.
  • Slide Out Indoor fan assembly for added service convenience.
  • Base pan with drawn supply and return opening for superior water management.
  • Forkable base rails for easy handling and lifting.

 

Download PDF version Download PDF version