Rheem RKNL-B072CL15E Packaged Unit

Technical Specification

Features:
  • Make: Rheem
  • Model code: RKNL-B072CL15E
  • Series: RKNL
  • Electrical: 208-230/3/60 V/phase/Hz
  • Refrigerant Type: R-410a
Additional info:

R-410A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Single stage compressor on B073 model. Dual stage compressor on B090 – B151 models. Convertible airflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models.  Solid Core liquid line filter drier on each circuit. Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies. Cooling operation up to 125 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. One piece top cover and one piece base pan with drawn supply and return opening for superior water management.  

Read more
Make Rheem
Manufacturer Rheem Manufacturing
Category Cooling>Packaged Units/RTU
Model code RKNL-B072CL15E
Series RKNL
Electrical 208-230/3/60 V/phase/Hz
Refrigerant Type R-410a
Dimensions Height: 44 inches
Width: 58.75 inches
Depth: 93.69 inches
Additional info
  • R-410A HFC refrigerant.
  • Complete factory charged, wired and run tested.
  • Scroll compressors with internal line break overload and high-pressure protection.
  • Single stage compressor on B073 model.
  • Dual stage compressor on B090 – B151 models.
  • Convertible airflow.
  • TXV refrigerant metering system on each circuit.
  • High Pressure and Low Pressure/Loss of charge protection standard on all models. 
  • Solid Core liquid line filter drier on each circuit.
  • Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies.
  • Cooling operation up to 125 degree F ambient.
  • Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream.
  • Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers.
  • Slide Out Indoor fan assembly for added service convenience.
  • One piece top cover and one piece base pan with drawn supply and return opening for superior water management.

 

Download PDF version Download PDF version
vfd