Nortek CW-DRU-12 Chilled Water Data Room Cooling Unit

Technical Specification

Features:
  • Make: Nortek
  • Model code: CW-DRU-12
  • Weight: 3300 ~ 4150 lbs
Additional info:

Designed for high density load areas where a large cooling duty is required from a compact footprint, and to provide the reliability and redundancy required for the critical application of data center cooling Designed for either downflow or upflow service Has energy reduction features as well as heating or humidification options Optimized chilled water coil with low air and waterside pressure drop Longer filter life and reduced pressure drop due to larger filter area More efficient direct-drive fans with higher static pressure capability than EC fans Improved uniformity of air flow over coils and in velocity from plenum Where required, can be supplied with electrode boiler humidifiers providing high efficiency stepless output of sterile steam and electric heaters are available if reheat is required FANWALL TECHNOLOGY® provides even, efficient air supply and inherent redundancy Fitted with a fully programmable direct digital controller (DDC) or industrial PLC controller complete with display/user interface The controller monitors the temperature and relative humidity and activates cooling humidification or dehumidification to provide precise and efficient conditioning of the supply air Additionally, the DDC controller monitors the in-built safety devices of the unit, which constantly monitor the healthy state of key components In the unlikely event of a component malfunction, the item is automatically isolated to enable the plant to continue running, and an alarm signal will be generated

Read more
Make Nortek
Manufacturer Nortek Global HVAC
Category Cooling>Data Center Coolers
Model code CW-DRU-12
Weight 3300 ~ 4150 lbs
Additional info
  • Designed for high density load areas where a large cooling duty is required from a compact footprint, and to provide the reliability and redundancy required for the critical application of data center cooling
  • Designed for either downflow or upflow service
  • Has energy reduction features as well as heating or humidification options
  • Optimized chilled water coil with low air and waterside pressure drop
  • Longer filter life and reduced pressure drop due to larger filter area
  • More efficient direct-drive fans with higher static pressure capability than EC fans
  • Improved uniformity of air flow over coils and in velocity from plenum
  • Where required, can be supplied with electrode boiler humidifiers providing high efficiency stepless output of sterile steam and electric heaters are available if reheat is required
  • FANWALL TECHNOLOGY® provides even, efficient air supply and inherent redundancy
  • Fitted with a fully programmable direct digital controller (DDC) or industrial PLC controller complete with display/user interface
  • The controller monitors the temperature and relative humidity and activates cooling humidification or dehumidification to provide precise and efficient conditioning of the supply air
  • Additionally, the DDC controller monitors the in-built safety devices of the unit, which constantly monitor the healthy state of key components
  • In the unlikely event of a component malfunction, the item is automatically isolated to enable the plant to continue running, and an alarm signal will be generated
Download PDF version Download PDF version