Prompt action by Green Point UK, BITZER UK's compressor remanufacturing and services arm, ensured critical cooling at a major UK data center was maintained following the failure of several chillers at the site.

The loss of cooling capacity meant the data center was vulnerable to a spike in ambient temperatures or an increase in the intensity of server usage, which could have overloaded the remaining cooling plant at the site, with potentially catastrophic consequences. 

proactive approach

Will Pribyl, General Manager of Green Point UK, said, "Due to system issues, several chillers on site had gone down and the data center was vulnerable. The work needed to be done immediately to ensure continuity of cooling, and the on-site contractor was under pressure to solve the problem."

The company was contacted due to its proactive approach and ability to guarantee the remanufacture of compressors regardless of their mechanical and electrical condition once units have been stripped down. 

data center cooling optimization

The company upgraded the compressors to the latest BITZER specification improving efficiency

Green Point UK fast-tracked full strip-down and remanufacture of five BITZER CSH95111 and CSH95113 semi-hermetic screw compressors, which are optimized for data center cooling and use in air-cooled liquid chillers in UK conditions. 

As part of the remanufacturing process, the company upgraded the compressors to the latest BITZER specification, improving efficiency and ensuring compatibility with current-generation spare parts. 

contactless oil-level monitoring

The upgraded compressor has the same footprint but includes internal enhancements, including the replacement of the original float-type oil-level management control with an optical sensor for improved performance. 

The optical system provides contactless oil-level monitoring, ensuring the compressor has optimum lubrication at all times. 

energy performance and reliability

Will Pribyl adds, "The upgrade effectively took what were first generation units up to the same specification as BITZER's latest third generation units, improving energy performance and reliability, and ensuring spare part support for the foreseeable future." 

Green Point UK is supporting the contractor in improving the resilience of other data center facilities it is responsible for, including the use of monitoring via the BITZER Digital Network and reducing running costs with variable speed drives. 

Download PDF version Download PDF version

In case you missed it

LG Accelerates B2B Growth With Key Structural Changes
LG Accelerates B2B Growth With Key Structural Changes

LG Electronics (LG) announced a series of organizational changes and executive appointments following the approval of its board of directors. This restructuring aims to accelerate...

Shortwave Infrared Heating: SWIR: The Smart Choice For Warehouse Heating
Shortwave Infrared Heating: SWIR: The Smart Choice For Warehouse Heating

For warehouse and factory owners, cutting their heat energy bills by over 90% might seem like a pipedream. I’ve been in enough warehouses to know one thing: heating them is e...

Genea And Siemens Partner To Enhance Physical Security Solutions
Genea And Siemens Partner To Enhance Physical Security Solutions

Siemens and Genea recently announced a second collaborative effort to provide security professionals and facility managers with improved security using the cloud. The security so...

vfd