Blalock Heating & Air, along with Johnstone Supply, Fujitsu and The Nixon Group, teamed up on a project at Speedway Ford in Griffin, Georgia, United States of America (USA).

The team consisted of:

  • Blalock Heating and Air – Justin Bishop,
  • Johnstone Supply – Ty Rath,
  • Fujitsu – Shawn Hill,
  • The Nixon Group – Seth Nixon.

Speedway Ford

Speedway Ford has been a long time customer of Blalock Heating & Air

Speedway Ford has been a long time customer of Blalock Heating & Air. The original equipment at Speedway Ford was nearly 30 years old. It consisted of a 1 – 10-ton and 1 – 6-ton split system that serviced the showroom and offices. Both systems had fan/coil units in the attic with straight ac’s outside and 200k btu Reznor inline duct heaters.

Speedway Ford saw that the cost to maintain and service the existing systems had become pretty expensive and when they began to look at replacement options, the logistics of trying to remove the existing equipment and replace it with new unitary product of the same size was going to be a task, simply because of the size of the new and old equipment.

HVAC system replacement and upgrade in two stages

The decision was made to complete job in two stages. The first stage was the removal of the 16 tons of unitary that serviced the offices/conference room/bathrooms/waiting area and showroom. Blalock Heating & Air went back with 18 tons of VRF, 1 – 10-ton VII to service the showroom that has 6 – 2-ton cassettes and 1 – 8-ton VII to service the offices/bathrooms/conference room/waiting area.

That system has 1 – 9k and 1 – 12k btu cassettes for the offices, 2 – 1-ton cassettes for the showroom, 2 – 2-ton medium static ducted units for the common areas. This stage of the install was done to help save money on energy bills and improve the overall comfort and service of the building.

Climate controlled area for the mechanics to work

The second stage of the job was completed about two years later with Blalock Heating & Air installing 28 tons of VII VRF into the main mechanic shop area of the building. This area of the building hasn’t ever been conditioned, with the exception of a couple of hanging heaters that didn’t really do too much, as far as heating the space.

This stage of the job was completed with the intention of providing a climate controlled area for the mechanics to work.

Fujitsu system installed

The benefits to the project were totally achieved once the Fujitsu system was installed. Since the initial install, Speedway Ford has noticed a savings of around US$ 2000.00/month on their gas bills throughout the heating season and an overall savings of around US$ 300.00 - US$ 500.00/month on electricity.

Download PDF version Download PDF version

In case you missed it

2025 AHR Expo: Top Innovations In HVACR Announced
2025 AHR Expo: Top Innovations In HVACR Announced

The AHR Expo (International  Air-Conditioning, Heating, Refrigerating Exposition) today announced the winners of the 2025 AHR Expo Innovation Awards. Winners are chosen annua...

Johnson Controls Center Develops And Tests HVAC Systems For Data Centers
Johnson Controls Center Develops And Tests HVAC Systems For Data Centers

Johnson Controls’ Advanced Development Engineering Center (JADEC) in New Freedom, PA., about 25 miles from Philadelphia, highlights and demonstrates the company’s capab...

Airzone Aidoo Pro Enhances VRF Energy Efficiency
Airzone Aidoo Pro Enhances VRF Energy Efficiency

The Olsen Group, based in Boca Raton, Florida, is a national pioneer in HVAC energy optimization. Donald Olsen and his seasoned team of HVAC control specialists have been in busine...

vfd