Airedale is excited to announce the launch of the DCSTM range, a family of air-cooled chillers specifically optimized for demanding data center environments, featuring ground-breaking Enhanced Free CoolingTM technology.

With uptime and energy efficiency hard-wired into every facet of their design, the DCSTM range has evolved from decades of worldwide data center experience. The range has been specifically designed by the Data Centre Solutions team, based at Airedale’s global headquarters in Leeds, UK, to deliver powerful, reliable, and sustainable cooling in the most demanding of environments.

Head pressure control

Utilizing existing Airedale chiller platforms, DeltaChillTM, TurboChillTM, and OptiChillTM, the DCS team has implemented multiple upgrades to meet the unique requirements of the data center market. Enhanced controls functionality, such as compressor fast-start and optimized head pressure control, has been added along with hardware upgrades such as battery-free UPS and Automatic Transfer Switches to conserve uptime.

The chillers are also designed to operate at increased supply/return water temperatures

The chillers are also designed to operate at increased supply/return water temperatures (20/32oC), in line with data center trends, and to maximize free cooling potential. Available with a range of compressor technologies and refrigerants, including low GWP option R1234ze, and featuring the Enhanced Free Cooling package, this range of super-high efficiency chillers offers unparalleled energy savings and a much-reduced carbon footprint.

Less mechanical cooling

With a complete redesign of the V-block condenser coils and the implementation of larger EC fans to maximize airflow, the Enhanced Free Cooling package is able to deliver a higher percentage of full free cooling over the course of a year. The mechanical upgrades, coupled with the ability of the DCS chillers to operate at increased maximum supply/return water temperatures, can deliver up to 39% annual energy cost savings over traditional free cooling methods.

The reduced requirement for less mechanical cooling, in turn, reduces the stress on components such as compressors, thus reducing maintenance requirements and increasing the longevity of the unit. Over its full life cycle, the combination of reduced energy consumption and lower approach temperatures leads to improved PUEs, allowing data center operators to meet their environmental targets.

  • Larger 910mm EC fans deliver increased airflow (compared to 800mm on standard units)
  • 5 rows of free cooling coils for increased free cooling capacity (compared to 3 rows on standard units)
  • Increased maximum supply/return water temperatures, up to a maximum of 20/32°C (68/90°F)
  • Closer approach temperatures

Worldwide efficiency targets

Patrick Cotton, Product Manager for chillers at Airedale, said, “In modern high-capacity data centers, balancing performance with sustainability, without compromising, is a priority, as data center operators work hard to reduce their carbon footprint whilst maintaining availability during a global surge in demand for data. Working closely with some of the world’s largest data center operators, we have been able to design and deliver our DCS range of chiller products to meet worldwide efficiency targets, whilst delivering the future of data center cooling.”

The DCSTM chiller range includes TurboChill DCSTM (200kW to 1830kW), DeltaChill DCSTM (110kW to 1100kW) and OptiChill DCS™ (1850kW). Enhanced Free Cooling is available on TurboChill DCS and DeltaChill DCS.

Download PDF version Download PDF version

In case you missed it

2025 AHR Expo: Top Innovations In HVACR Announced
2025 AHR Expo: Top Innovations In HVACR Announced

The AHR Expo (International  Air-Conditioning, Heating, Refrigerating Exposition) today announced the winners of the 2025 AHR Expo Innovation Awards. Winners are chosen annua...

Johnson Controls Center Develops And Tests HVAC Systems For Data Centers
Johnson Controls Center Develops And Tests HVAC Systems For Data Centers

Johnson Controls’ Advanced Development Engineering Center (JADEC) in New Freedom, PA., about 25 miles from Philadelphia, highlights and demonstrates the company’s capab...

Airzone Aidoo Pro Enhances VRF Energy Efficiency
Airzone Aidoo Pro Enhances VRF Energy Efficiency

The Olsen Group, based in Boca Raton, Florida, is a national pioneer in HVAC energy optimization. Donald Olsen and his seasoned team of HVAC control specialists have been in busine...

vfd