Luxaire PJ-15 Split system heat pump

Technical Specification

Features:
  • Make: Luxaire
  • Model code: PJ-15
  • Height: 44.5 inches
  • Width: 64.1 inches
  • Depth: 59.1 inches
Additional info:

Meets EPACT 2005 and exceeds ASHRAE 90.1-1999 efficiency standards Inherently protected condenser fan motors Five-minute, anti-short cycle timer and minimum compressor run time Factory-installed disconnects, convenience outlet and technical coil option Durable build with condenser coils constructed with microchannel aluminum tubing and aluminum fins Self-contained, high and low pressure controls Class 2, 24-volt, thermostat control circuit Compressor staging for capacity reduction provides more economical operation and even temperature levels within the conditioned space Includes filter drier ready for field installation and is Smart Equipment enabled 2-pipe and 4-pipe configurations Standard operation to 40°F; factory or field-installed low-ambient VFD control to 0°F Scroll compressors provide both high efficiency and reliability Crankcase heaters that will be de-energized when the compressor is operating Solid state or internal line break compressor motor protection Copper stub-outs are factory-mounted on the suction and liquid lines to simplify field piping connections

Read more
Make Luxaire
Manufacturer Luxaire
Category Heating>Heat Pumps
Model code PJ-15
Dimensions Height: 44.5 inches
Width: 64.1 inches
Depth: 59.1 inches
Additional info
  • Meets EPACT 2005 and exceeds ASHRAE 90.1-1999 efficiency standards
  • Inherently protected condenser fan motors
  • Five-minute, anti-short cycle timer and minimum compressor run time
  • Factory-installed disconnects, convenience outlet and technical coil option
  • Durable build with condenser coils constructed with microchannel aluminum tubing and aluminum fins
  • Self-contained, high and low pressure controls
  • Class 2, 24-volt, thermostat control circuit
  • Compressor staging for capacity reduction provides more economical operation and even temperature levels within the conditioned space
  • Includes filter drier ready for field installation and is Smart Equipment enabled
  • 2-pipe and 4-pipe configurations
  • Standard operation to 40°F; factory or field-installed low-ambient VFD control to 0°F
  • Scroll compressors provide both high efficiency and reliability
  • Crankcase heaters that will be de-energized when the compressor is operating
  • Solid state or internal line break compressor motor protection
  • Copper stub-outs are factory-mounted on the suction and liquid lines to simplify field piping connections
Download PDF version Download PDF version
vfd