Fraser-Johnston YJ-50 Split Condensing unit

Technical Specification

Features:
  • Make: Fraser-Johnston
  • Model code: YJ-50
  • Capacity: >5 tons
  • Refrigerant Lines - Liquid/Suction: 7/8 / 1-5/8 inches
  • Refrigerant Type: R-410a
Additional info:

Meets or exceeds ASHRAE 90.1-2007 Standard Inherently protected condenser fan motors Standard operation to 40°F; factory- or field-installed, low-ambient VFD control to 0°F Scroll compressors provide both high efficiency and reliability Crankcase heaters that de-energize when the compressor is operating Solid state or internal line break compressor motor protection Lockout circuit prevents the unit from cycling on safety control Factory-testing of each compressor, condenser fan motor, crankcase heater and electrical control circuit assures trouble-free startup and years of reliable operation Smart Equipment enabled Five-minute anti-short cycle timer and minimum compressor run time Factory-installed disconnects, convenience outlet and a Technicoat brand coil coat option Condenser coils constructed of microchannel aluminum tube and aluminum fins for durability and long-lasting, efficient operation Self-contained high and low pressure controls Class 2, 24-volt thermostat control circuit Multiple controls to provide stable system operation at ambient temperatures down to 40° F with kits available for operation to 0° F

Read more
Make Fraser-Johnston
Manufacturer Fraser-Johnston Heating & Air Conditioning
Category Cooling>Split Condensers
Model code YJ-50
Capacity >5 tons
Refrigerant Lines - Liquid/Suction 7/8 / 1-5/8 inches
Refrigerant Type R-410a
Weight 2345 lbs
Dimensions Height: 57.7 inches
Width: 88.5 inches
Depth: 128.5 inches
Additional info
  • Meets or exceeds ASHRAE 90.1-2007 Standard
  • Inherently protected condenser fan motors
  • Standard operation to 40°F; factory- or field-installed, low-ambient VFD control to 0°F
  • Scroll compressors provide both high efficiency and reliability
  • Crankcase heaters that de-energize when the compressor is operating
  • Solid state or internal line break compressor motor protection
  • Lockout circuit prevents the unit from cycling on safety control
  • Factory-testing of each compressor, condenser fan motor, crankcase heater and electrical control circuit assures trouble-free startup and years of reliable operation
  • Smart Equipment enabled
  • Five-minute anti-short cycle timer and minimum compressor run time
  • Factory-installed disconnects, convenience outlet and a Technicoat brand coil coat option
  • Condenser coils constructed of microchannel aluminum tube and aluminum fins for durability and long-lasting, efficient operation
  • Self-contained high and low pressure controls
  • Class 2, 24-volt thermostat control circuit
  • Multiple controls to provide stable system operation at ambient temperatures down to 40° F with kits available for operation to 0° F
Download PDF version Download PDF version
vfd