Data Aire DAMW-2.5 Water Cooled Packaged Spot-cooling System

Technical Specification

Features:
  • Make: Data Aire
  • Model code: DAMW-2.5
  • Series: Mini Ceiling DX
  • Refrigerant Type: R-410a
  • Weight: 350 lbs
Additional info:

The perfect environmental control system for small computer centers, electronic, telephone, and battery rooms, or wherever spot cooling may be necessary and space is a problem Precise temperature regulation is provided by a built-in control system A factory installed microswitch will disable the unit prior to condensate pan overflow should the drain line become plugged with debris A 2 inch, MERV 8 efficient filter (based on ASHRAE Std. 52.2) is provided behind the return air grille The cabinet houses the evaporator section, evaporator blower assembly, filter section (located in air distribution plenum), and the condenser coil In addition, a high efficiency plate fin condenser with head pressure activated 2-way water regulating valve is built into the refrigeration system and is contained in the evaporator section The blower assembly is a draw-through type with a centrifugal, forward curved, double width, double inlet blower configuration engineered for quiet, reliable operation The belt driven variable pitch drive provides adjustable air flow capability to match the requirements of the controlled space The draw-through design insures even distribution across the coil, low internal cabinet losses, and static sealing of the filter section The motor has internal overload protection and is mounted on an adjustable slide base

Read more
Make Data Aire
Manufacturer Data Aire Inc.
Category Cooling>Data Center Coolers
Model code DAMW-2.5
Series Mini Ceiling DX
Refrigerant Type R-410a
Weight 350 lbs
Additional info
  • The perfect environmental control system for small computer centers, electronic, telephone, and battery rooms, or wherever spot cooling may be necessary and space is a problem
  • Precise temperature regulation is provided by a built-in control system
  • A factory installed microswitch will disable the unit prior to condensate pan overflow should the drain line become plugged with debris
  • A 2 inch, MERV 8 efficient filter (based on ASHRAE Std. 52.2) is provided behind the return air grille
  • The cabinet houses the evaporator section, evaporator blower assembly, filter section (located in air distribution plenum), and the condenser coil
  • In addition, a high efficiency plate fin condenser with head pressure activated 2-way water regulating valve is built into the refrigeration system and is contained in the evaporator section
  • The blower assembly is a draw-through type with a centrifugal, forward curved, double width, double inlet blower configuration engineered for quiet, reliable operation
  • The belt driven variable pitch drive provides adjustable air flow capability to match the requirements of the controlled space
  • The draw-through design insures even distribution across the coil, low internal cabinet losses, and static sealing of the filter section
  • The motor has internal overload protection and is mounted on an adjustable slide base