Data Aire DAMA-02-P Air Cooled Packaged Spot-cooling System

Technical Specification

Features:
  • Make: Data Aire
  • Model code: DAMA-02-P
  • Series: Mini Ceiling DX
  • Refrigerant Type: R-410a
  • Weight: 425 lbs
Additional info:

The perfect environmental control system for small computer centers, electronic, telephone, and battery rooms, or wherever spot cooling may be necessary and space is a problem Precise temperature regulation is provided by a built-in control system A factory installed microswitch will disable the unit prior to condensate pan overflow should the drain line become plugged with debris A 2 inch, MERV 8 efficient filter (based on ASHRAE Std. 52.2) is provided behind the return air grille The cabinet houses the evaporator section, evaporator blower assembly, filter section (located in air distribution plenum), and the condenser coil The blower assembly is a draw-through type with a centrifugal, forward curved, double width, double inlet blower configuration engineered for quiet, reliable operation The belt driven variable pitch drive provides adjustable air flow capability to match the requirements of the controlled space The draw-through design insures even distribution across the coil, low internal cabinet losses, and static sealing of the filter section The motor has internal overload protection and is mounted on an adjustable slide base

Read more
Make Data Aire
Manufacturer Data Aire Inc.
Category Cooling>Data Center Coolers
Model code DAMA-02-P
Series Mini Ceiling DX
Refrigerant Type R-410a
Weight 425 lbs
Additional info
  • The perfect environmental control system for small computer centers, electronic, telephone, and battery rooms, or wherever spot cooling may be necessary and space is a problem
  • Precise temperature regulation is provided by a built-in control system
  • A factory installed microswitch will disable the unit prior to condensate pan overflow should the drain line become plugged with debris
  • A 2 inch, MERV 8 efficient filter (based on ASHRAE Std. 52.2) is provided behind the return air grille
  • The cabinet houses the evaporator section, evaporator blower assembly, filter section (located in air distribution plenum), and the condenser coil
  • The blower assembly is a draw-through type with a centrifugal, forward curved, double width, double inlet blower configuration engineered for quiet, reliable operation
  • The belt driven variable pitch drive provides adjustable air flow capability to match the requirements of the controlled space
  • The draw-through design insures even distribution across the coil, low internal cabinet losses, and static sealing of the filter section
  • The motor has internal overload protection and is mounted on an adjustable slide base