Carrier 39MN08W AERO® Semi-Custom Central Station Air Handler

Technical Specification

Features:
  • Make: Carrier
  • Model code: 39MN08W
  • Series: AERO® 39M
  • Filters: HEPA
  • Quantity: 4000 CFM
Additional info:

Performance Features All units are shrink wrapped for complete protection while in transit Maximum deflection ratio of L/240 at 8 in. wg. Casing air leakage rate less than 1% at 8 in. wg. of unit nominal airflow Doublewall panel construction, insulation is sealed between the inner and outer panels Thermal break casing construction Optional factory mounted controls Chilled water, hot water, direct expansion (DX), electric and steam coils Tubular indirect fired gas furnace option with a minimum of 10:1 turndown Ultraviolet band C (UV-C) germicidal lamps Multiple filtration from pleated MERV 8 to HEPA filters Energy recovery ventilator (ERV) sections Multiple fan options Humidifiers for precise indoor climate conditioning Internal and external face and bypass damper sections Reliability Features Optional 18 gauge exterior and/or interior skin Standard insulated, fully drainable, sloped drain pans in galvanized or stainless steel Maintenance Features Optional prepainted and/or galvanized unit exterior Optional aluminum diamond treadplate floors All service may be performed through large, removable or hinged with lockable handle panels Marine lights and viewports for interior component inspection Installation Features Units may be mounted in ceilings, closets, attics, etc. Variable frequency drives are programmed and started up at the factory Casing can be broken-down to individual panels and frame members

Read more
Make Carrier
Manufacturer Carrier Corporation
Category Cooling>Air Handling Units
Model code 39MN08W
Series AERO® 39M
Filters HEPA
Quantity 4000 CFM
Placement Indoor
Width 54 inches
Height 40 inches
Additional info

Performance Features

  • All units are shrink wrapped for complete protection while in transit
  • Maximum deflection ratio of L/240 at 8 in. wg.
  • Casing air leakage rate less than 1% at 8 in. wg. of unit nominal airflow
  • Doublewall panel construction, insulation is sealed between the inner and outer panels
  • Thermal break casing construction
  • Optional factory mounted controls
  • Chilled water, hot water, direct expansion (DX), electric and steam coils
  • Tubular indirect fired gas furnace option with a minimum of 10:1 turndown
  • Ultraviolet band C (UV-C) germicidal lamps
  • Multiple filtration from pleated MERV 8 to HEPA filters
  • Energy recovery ventilator (ERV) sections
  • Multiple fan options
  • Humidifiers for precise indoor climate conditioning
  • Internal and external face and bypass damper sections

Reliability Features

  • Optional 18 gauge exterior and/or interior skin
  • Standard insulated, fully drainable, sloped drain pans in galvanized or stainless steel

Maintenance Features

  • Optional prepainted and/or galvanized unit exterior
  • Optional aluminum diamond treadplate floors
  • All service may be performed through large, removable or hinged with lockable handle panels
  • Marine lights and viewports for interior component inspection

Installation Features

  • Units may be mounted in ceilings, closets, attics, etc.
  • Variable frequency drives are programmed and started up at the factory
  • Casing can be broken-down to individual panels and frame members
Download PDF version Download PDF version