Ruud RHXP3610SPANJAU05 Low Height Air Handler

Technical Specification

Features:
  • Make: Ruud
  • Model code: RHXP3610SPANJAU05
  • Quantity: 1200 CFM
  • Height: 10 inches
Additional info:

Standard Features High efficiency ECM motor Drain pan has 3/4" NPT primary an secondary (overflow) fittings 240V motor, 24V control Factory installed electric heat (up to 10kW) (except 0 kW models) Highly efficient copper tube/aluminum fin cooling coil with factory installed R-410A TXV (non-bleed type) Insulated and coated galvanized steel drain pan, sloped for positive drainage Effective January 2016, Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193. Optional Features Attractive off-white return air/access panel with captive screws. They can be used with either the non-enclosed RXHT or the TXHT with a field or factory installed enclosure. IAQ filter panels Field installed enclosure. All enclosures are fully insulated and include cutouts for optional ducted return air. Ducted return air option requires remote filter-grille. Heat pump kit - required for all models having electric heat (#942-1) Condensate overflow switch (# SS3) (field installed) Enclosure "Cap Kit" - for ceiling installation

Make Ruud
Manufacturer Ruud
Model code RHXP3610SPANJAU05
Quantity 1200 CFM
Height 10 inches
Additional info

Standard Features

  • High efficiency ECM motor
  • Drain pan has 3/4" NPT primary an secondary (overflow) fittings
  • 240V motor, 24V control
  • Factory installed electric heat (up to 10kW) (except 0 kW models)
  • Highly efficient copper tube/aluminum fin cooling coil with factory installed R-410A TXV (non-bleed type)
  • Insulated and coated galvanized steel drain pan, sloped for positive drainage
  • Effective January 2016, Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193.

Optional Features

  • Attractive off-white return air/access panel with captive screws. They can be used with either the non-enclosed RXHT or the TXHT with a field or factory installed enclosure.
  • IAQ filter panels
  • Field installed enclosure. All enclosures are fully insulated and include cutouts for optional ducted return air. Ducted return air option requires remote filter-grille.
  • Heat pump kit - required for all models having electric heat (#942-1)
  • Condensate overflow switch (# SS3) (field installed)
  • Enclosure "Cap Kit" - for ceiling installation