Amana ALZT7CA3610A* High-Efficiency Heat Pump Two-Stage

Technical Specification

Features:
  • Make: Amana
  • Model code: ALZT7CA3610A*
  • Series: ALZT7CA
  • Height: 35¾ inches
  • Width: 35½ inches
Additional info:

Two-Stage Copeland® UltraTech scroll compressor High-density foam compressor sound blanket Integrated communicating ComfortBridge™ technology Commissioning and diagnostics via indoor board Bluetooth with the CoolCloud™ phone and tablet application Amana® Brand Smart Thermostat Compatibility ComfortAlert™ built in diagnostics Copper tube/enhanced aluminum fin coil - 5mm on 2.0-3.0T Copper tube/enhanced aluminum fin coil -7mm on 4.0-5.0 T Simple low-voltage wiring to outdoor unit in communicating mode Diagnostic indicator lights and storage of six fault codes Color-coded terminal strip for non-communicating set-up High- and low-pressure switches Time-delay technology with short-cycle protection to ensure quiet, reliable defrost Factory-installed bi-flow liquid-line filter drier Factory-installed suction-line accumulator Factory-installed compressor crankcase heater Factory-installed high-capacity muffler Factory-installed coil and ambient temperature sensors AHRI Certified; ETL Listed

Read more
Make Amana
Manufacturer Amana
Category Heating>Heat Pumps
Model code ALZT7CA3610A*
Series ALZT7CA
Dimensions Height: 35¾ inches
Width: 35½ inches
Depth: 35½ inches
Additional info
  • Two-Stage Copeland® UltraTech scroll compressor
  • High-density foam compressor sound blanket
  • Integrated communicating ComfortBridge™ technology
  • Commissioning and diagnostics via indoor board Bluetooth with the CoolCloud™ phone and tablet application
  • Amana® Brand Smart Thermostat Compatibility
  • ComfortAlert™ built in diagnostics
  • Copper tube/enhanced aluminum fin coil - 5mm on 2.0-3.0T
  • Copper tube/enhanced aluminum fin coil -7mm on 4.0-5.0 T
  • Simple low-voltage wiring to outdoor unit in communicating mode
  • Diagnostic indicator lights and storage of six fault codes
  • Color-coded terminal strip for non-communicating set-up
  • High- and low-pressure switches
  • Time-delay technology with short-cycle protection to ensure quiet, reliable defrost
  • Factory-installed bi-flow liquid-line filter drier
  • Factory-installed suction-line accumulator
  • Factory-installed compressor crankcase heater
  • Factory-installed high-capacity muffler
  • Factory-installed coil and ambient temperature sensors
  • AHRI Certified; ETL Listed
Download PDF version Download PDF version
vfd